SciCANN which has been working in the Cannabis industry for 15 years. The SciCANN division of Scientific Equipment Source Inc is your source for new and refurbished Cannabis quality control laboratory testing equipment. We supply HPLC, GC, NIR, and more for Potency, terpenes, R&D, Residual solvents, moisture content, pesticide screening, microbiological purity, aflatoxins and more as well as consult on the LP process.

Microplate Reader, Molecular Devices Spectramax, Refurbished

$9,500.00

The SPECTRAmax™ PLUS microplate spectrophotometer provides rapid and sensitive UV/VIS measurements of a variety of analytes including specific proteins, nucleic acids, and other molecules across a wide range of concentrations. It measures the optical density (OD) of samples in both 96- and 384-well microplates or in a cuvette at a selected wavelength for a single point in time (endpoint), over a specified period of time (kinetic), or over a selected wavelength range (spectral scan).

Description

The SPECTRAmax™ PLUS microplate spectrophotometer provides rapid and sensitive UV/VIS measurements of a variety of analytes including specific proteins, nucleic acids, and other molecules across a wide range of concentrations. It measures the optical density (OD) of samples in both 96- and 384-well
microplates or in a cuvette at a selected wavelength for a single point in time (endpoint), over a specified period of time (kinetic), or over a selected wavelength range (spectral scan).

Specifications
Technical specifications are subject to change without notice.
Photometric Performance
Wavelength range 190–1000 nm
Wavelength selection Monochromator tunable in 1-nm increments
Wavelength bandwidth £ 2.0 nm FWHM (full width half maximum)
Wavelength accuracy ± 1.0 nm across wavelength range
Wavelength repeatability ± 0.2 nm across all optical channels
Photometric range -0.3 to 4.000 OD
Photometric resolution 0.001 OD
Photometric accuracy/linearity
(microplate), 0–2.0 OD: 190–1000 nm <± 1.0% and ± 0.006 OD Photometric accuracy/linearity (cuvette), 0–2.0 OD: 90–1000 nm <± 1.0% and ± 0.005 OD Photometric precision (repeatability), 0–2.0 OD: 190–1000 nm <± 1.0% and ± 0.003 OD Stray light £ 0.05% at 230 nm Photometric stabilization Instantaneous Photometric drift None—continuous referencing of monochromatic output Calibration Automatic before first kinetic read and before every endpoint reading Optical alignment None required Light source Xenon flash lamp (5 watts) Average lamp lifetime 1 billion flashes Illumination Top down (microplates); horizontal (cuvettes) Photodetectors Silicon photodiode Instrument Description Photometric Analysis Modes Stand-Alone • Single wavelength Absorbance or %Transmittance reading of the cuvette (or test tube) Using SOFTmax PRO • Express data as Absorbance or %Transmittance • Single wavelength reading of microplate and/or cuvette • Multiple wavelength (up to six) reading of microplate and/ or cuvette • Kinetic and kinetic graphics of microplate and/or cuvette • Spectral scan (190–1000 nm) of microplate and/or cuvette Measurement Time (calibration off) Microplate Read time (endpoint) Standard read • 96 wells in 12 seconds (single wavelength) • 96 wells in 12*N seconds (N wavelengths) Speed read • 96 wells in 5 seconds (single wavelength) • 96 wells in 5*N seconds (N wavelengths) Kinetic read intervals • 96 wells, 9-second minimum interval between readings (single wavelength) • 1 column, 2-second minimum interval between readings (single wavelength) Cuvette Read time (endpoint) • 1 second (single wavelength) Kinetic read intervals • 2-second minimum interval between readings (single wavelength) Scan Speed Cuvette: Normal scan 60*K nm/min (K = wavelength interval) Cuvette: Speed scan 200*K nm/min Microplate: Normal scan 33*K nm/min (8-well strip) Microplate: Speed scan 135*K nm/min (8-well strip) The on-board microprocessor calculates and reports the absorbance (or % Transmittance) for each well of a microplate. Data from multiple wavelengths can be acquired during a single reading, if desired, and different calculations can be made based on this data using SOFTmax PRO software, including the subtraction of blanks, use of standard curves, etc. Typical applications include endpoint assays (quantitation of cytoproliferation by MTT reduction, colorimetric protein assays, protein measurement at 280 nm, DNA/RNA measurement at 260 nm, and endpoint ELISAs) and kinetic measurements (enzyme studies, such as determination of the activity of enzymes released from cells, and kinetic ELISAs). All standard 96- and 384-well microplates, strip wells, and filter-bottom microplates can be used in the SPECTRAmax PLUS 384. When reading at wavelengths below 340 nm, special UV-transparent, disposable or quartz microplates and cuvettes that allow transmission of the far UV spectra must be used. With SOFTmax PRO, the contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, making it possible to perform kinetic analysis of solid-phase, enzyme-mediated reactions (mixing is not critical for liquid-phase reactions). The temperature of the microplate chamber can also be regulated, if desired, from 4°C above ambient to 45°C.

×
×