SciCANN which has been working in the Cannabis industry for 15 years. The SciCANN division of Scientific Equipment Source Inc is your source for new and refurbished Cannabis quality control laboratory testing equipment. We supply HPLC, GC, NIR, and more for Potency, terpenes, R&D, Residual solvents, moisture content, pesticide screening, microbiological purity, aflatoxins and more as well as consult on the LP process.

RENTAL, Centrifuge, High Capacity (6L) Floor Model, Refrigerated, Beckman J-6B with 6 pl rotor, Refurbished

$550.00

RENTAL, Centrifuge, High Speed High Capacity Floor Model, Refrigerated, Beckman J-6B with 6 pl rotor, Refurbished
Centrifuge rpm to 6,000
JS-4.2 Rotor: 6 places x 1000ml goes to 4200rpm

Description

The Beckman J6-B High Capacity Centrifuge features an extensive list of functionalities including a conventional brush motor and reliable analog display. This Beckman model also features an advanced refrigeration option, a performance speed of 6000 rpm, and a maximum force of 6835 g.

Beckman J6-B High Capacity Centrifuge Specifications

Maximum Speed 6000 rpm
Maximum Speed Any speed outside the rotor’s critical speed range (~600 to 800rpm). Critical speed is the speed at which a rotor shifts from rotation about its center of mass. Critical Speed is characterized by some vibration.
Maxium RCF 6840 x g
Maximum Rotor Capacity 6 liters
Driver System 1.2 kW (1 ½ hp) dc motor; belt-driven driveshaft.
Speed Control Rotor Speed meter reading is within 50 rpm of setting on Speed dial, and within 150 rpm of actual rotor speed. Control rage is 0 to 6000 rpm.
Acceleration Time Minimum 15 seconds (JA-21 rotor), maximum 2.5 minutes (JS-4.2 rotor).
Braking System Electronic, variable braking
Maximum Braking Time At maximum brake setting: no more than twice the acceleration time.
Temperature Control Sample temperature is within 2°C of the desired temperature; within 1° if calibration has also been performed.
Temperature Control Range 0 to 40°C at full speed; as low as -25°C at reduced speed
Ambient Range 16°C to 38°C (60°F to 100°F)
Maximum Heat Output (During Operation) 1.9 kW (6500 Btu/h)
Timer Times up to 30 minutes (60 Hz instruments) or 36 minutes (50 Hz instruments), or HOLD; graduated in 1-minute increments
Rotor Chamber Diameter 580 mm (23”)
Electrical Requirements 3-wire single phase
Range for 208V/60Hz 187-223 V
Range for 240V/60Hz 224-264 V
Range for 220V/50Hz 210-224 V
Dimensions Right side (for tilting up door): 150mm (6”)
Left side:150mm (6”)
Back( distance from condenser fins to wall, essential for adequate ventilation):150 mm (6”)
Net weight: 252kg (555 lbs)
Height to door top(door closed): 940mm (37”).
Height to work surface(door open): 910mm (35.5”)
Overall height: 1270mm(50”)
Overall width: 711mm (28”)
Overall depth(without bracker): 825mm (32.5”)
Height with door open (left side): 1600mm(63”)
Designed for optimal performance, the Beckman J6-B is equipped with a dynamic electric braking, high torque drive system, and three significant figures digital speed readout. To further enhance the functionalities of the J6-B system, users can integrate it with a high capacity JS-4.2 rotor with six large one-liter cups and a JS-5.2 rotor with four one-liter cups.

×
×