SciCANN which has been working in the Cannabis industry for 15 years. The SciCANN division of Scientific Equipment Source Inc is your source for new and refurbished Cannabis quality control laboratory testing equipment. We supply HPLC, GC, NIR, and more for Potency, terpenes, R&D, Residual solvents, moisture content, pesticide screening, microbiological purity, aflatoxins and more as well as consult on the LP process.

Spectrophotometer, UV-Vis, Varian Cary 50 bio, Refurbished

$6,990.00

Spectrophotometer, UV-Vis, Varian Cary 50 bio, Refurbished

Wavelength Range (nm) 190–1100
Wavelength Accuracy (nm) ±0.07 at 541.94 nm, ± 0.24 at 260.54 nm
Wavelength Reproducibility (nm) ±0.01
Beam Splitting System Beam splitter
Detectors Two silicon diode detectors
UV-Vis Limiting Resolution (nm) 1.5

Categories: ,

Description

Spectrophotometer, UV-Vis, Varian Cary 50 bio, Refurbished

The Varian Cary 50 Bio UV-Visible Spectrophotometer with Cary 16 Channel-MPM Code 1003-0203, has a data collection rate of 80 points per sec; a max scan rate is 24,000 nm per minute; Wavelength range of 190-1100 nm is scanable in less than 3 seconds; and measure samples up to 3 Abs. Excellent noise performance is achieved with the highly focussed and very intense light beam, even when using small aperture microcells. The Varian Cary 50’s super-concentrated beam makes it ideal for fibre optic work, offering excellent coupling efficiency and light throughput. Its room-light immunity makes shielding of a fibre optic probe unnecessary.

Specifications:
Grating Holographic, 27.5 x 35 mm, 1200 lines/mm, blaze angle 8.6° at 240 nm
Beam Splitting System Beam splitter
Detectors Two silicon diode detectors
UV-Vis Limiting Resolution (nm) 1.5
Toluene/Hexane Limiting Resolution Test 1.65
Stray Light (%T) at 198 nm (12 g/L KCl, TGA and BP/EP method) 0.53%
Stray Light at 220 nm (10 g/L NaI ASTM method) 0.02%
Stray Light at 370 nm (50 mg/L NaNO2) 0.018%
Wavelength Range (nm) 190–1100
Wavelength Accuracy (nm) ±0.07 at 541.94 nm, ± 0.24 at 260.54 nm
Wavelength Reproducibility (nm) ±0.01
Photometric Accuracy (Abs) Using NIST 930D filters at 1 Abs ±0.0007
Photometric Accuracy (Abs) Using NIST 930D filters at 0.2, 0.5 and 0.75 Abs (14.2% w/v KNO3, TGA method) ±0.01,
Photometric Accuracy (Abs) Using NIST 930 filters at 0.292 to 0.865 Abs (60.06 mg/L K2Cr2O7, BP method) ±0.01, 0.955 Abs
Photometric Accuracy (Abs) Using NIST 930 filters at 0.292 to 0.865 Abs (600.06 mg/L K2Cr2O7, BP method) ±0.012
Photometric Range (Abs) 3.3
Photometric Display ±9.9999 Abs, ±200.00 %T

×
×